Level 1 – 1 to 3 of the Devices Primary Characteristic’s Of Device is verified at 25C. This may include the following:
- Forward Bias
- Reverse Bias
- Breakdown Voltage
- Threshold Voltage
- On Resistance
- Av, hfe, or Gain
Level 2 – Testing of Level 1 parameters at Temperature (-55C, -40C, 0C, 25C, 70C, 85C, 125C).
Level 3 - Verification of All DC parameters to Manufactures Specification at 25C.